The Closter Environmental Commission is developing guidelines for green buildings. The EC independently reviews residential Planning Board applications against the 135-point checklist linked on this page. The “Green Score” indicates our assessment of sustainability features evidenced in the plans, including site, water, energy, envelope, and indoor features.

This is an experimental program; participation is voluntary and a high score is not a condition of approval. However it is an indication of best practices that residents and developers alike should consider, whether their goals are to save money or to decrease emissions.

The EC provides its assessments to the Planning Board, and offers free consultations on request. Please note that many projects can reach “Level 1” for a minimal cost premium, and that NJ state & utility incentives can often offset the bigger items.

Infographic: The Path to a Greener Closter Home — new projects typically start below 10 points at Level 0; adding a cold-climate heat pump (+4 pts), Level 2 EV charging circuit (+2), solar conduit pre-install (+1), above-code insulation (+3), passive radon mitigation, dark-sky lighting and native plantings reaches Level 1 at 25+ points.
The path from Level 0 to a certified Level 1 home — click to enlarge.

Green reviews

2026
353 Homans Avenue
StatusHearing Aug 27
1 flag open
ApplicationP-2026-08
New 1-family house with in-ground pool & spa
NotesSix 500-gallon seepage pits engineered to net-zero runoff. The 3-point tree credit awaits the surveyor’s count of qualifying trees; the pool equipment pad is sited but unspecified — the ideal moment to commit to efficient equipment.
Green ScoreLevel 03 / 135

90 Knickerbocker Road
StatusReconsideration Aug 27
ApplicationP-2026-05
Minor subdivision — two future homes, private road
NotesA conceptual subdivision — every item is honestly unknown, which makes this the docket’s highest-leverage case. The review recommends acknowledging voluntary green commitments for both future dwellings in any approving resolution.
Green ScoreLevel 00 / 135

98 Wainwright Avenue
StatusApproved Jun 25
ApplicationP-2026-06
New house, pool & spa, retaining walls
NotesFirst landscape credits of the docket — a 60%-native planting palette with pollinator species — plus a full stormwater design. The applicant’s own tree plan removes 14 of 20 existing trees, which the preservation credit cannot survive.
Green ScoreLevel 06 / 135

120 Hickory Lane
StatusApproved Apr 30
1 flag open
ApplicationP-2026-02
New house & pool, riparian lot
NotesUnderground utility service confirmed, and an infiltration system storing rooftop and pool runoff on a flood-hazard lot. Gas service is shown — the electrification menu remains fully open at building permit.
Green ScoreLevel 04 / 135

5 Pine Hill Road
Sources—
StatusExpected Sept 24
ApplicationP-2026-07
NotesReview begins when the application documents are posted to the Borough site.
Green Score— / 135
Review—

162 Anderson Avenue
Sources—
StatusExpected Sept 24
ApplicationP-2026-09
NotesReview begins when the application documents are posted to the Borough site.
Green Score— / 135
Review—

Reviewed — score published
Review pending
162 Anderson Ave: pin added when documents post

Statuses per posted Borough agendas and minutes as of August 23, 2026. Reviews are advisory and are not a condition of approval. Map data © OpenStreetMap contributors.


(Visited 37 times, 1 visits today)
Last modified: August 23, 2026